您的当前位置:主页 > 验厂消防指引

安全出口

建筑设计防火规范(GB50016—2014) 第6.4.11条
  
  防火规范 建筑设计 疏散门
  
  建筑内的疏散门应符合下列规定:
  
  1.民用建筑和厂房的疏散门,应采用向疏散方向开启的平开门,不应采用推拉门、卷帘门、吊门、转门和折叠门。除甲、乙类生产车间外,人数不超过 60人且每樘门的平均疏散人数不超迫 30人 的房间,其 疏散门的开启方向不限:
  
  2.仓库的疏散门应采用向疏散方向开启的平开门,但丙、丁、戊类仓库首层靠墙的外侧可采用推拉门或卷帘门;
  
  3.开向疏散楼梯或疏散楼梯间的门,当其完全开启时,不应减少楼梯平台的有效宽度:
  
  4.人员密集场所内平时需要控制人员随意 出入的疏散门和设置门禁系统的住宅、 宿舍、 公寓建筑的外门,应保证火灾时不需使用钥匙等任何工具即能从内部易于打开,并应在显著位置设置具有使用提示的标识。
  
  Code of Design on Building Fire Protection and Prevention (GB50016-2014), Article 6.4.11
  
  The evacuation door in the building shall meet the following requirements:
  
  1. The evacuation door in the civil building and factory building shall be opened towards the evacuation direction. The evacuation door of the civil building and factory shall be side-hung door, and shall not be sliding door, roller shutter, overhung door or revolving door. Except Class A, B factory building, there is no restriction on the opening direction of the door if there are no more than 60 persons in the room and the average evacuation capacity of each door is no more than 30 persons;
  
  2. The evacuation door of storage shall be side-hung door to the evacuation direction. Sliding door or roller shutter may be used at the outside surface of the wall on the first floor of Class C, D, E storage.
  
  3. The evacuation door, which opened towards evacuation stairs, when it is entirely opened, the width of the evacuation stairs should be guaranteed.
  
  4. The evacuation door that needs to be controlled for people going in and out at will in densely populated place or the outdoor of the residential building controlled by electric devices shall be opened easily from the inside without using any tools such as key etc. in case of fire. Signs and operation explanation shall be labeled at the well-marked place.



       验厂中对安全门要求:

      1、需要外开;

      2、不接受卷联门、侧拉门、内开门;

      3、门的宽度不能小于90CM,沃尔玛验厂不能小于100CM;

   4、需要从内部能打开;

      5、两个门之间的距离不能太小;

      6、特殊验厂需要防火门及闭门器;

      6、以下图片供参考: